Check back regularly or subscribe for updates. Email us at jandkaudiodesign@gmail.com, or fill in the form on the left.
Showing posts with label Q&A. Show all posts
Showing posts with label Q&A. Show all posts

Wednesday, March 18, 2020

Halt operations from 18th MAR till 31st MAR 2020 due to COVID-19.

J&K Audio Design has to halt operations from 18th MAR till 31st MAR 2020 due to COVID-19 outbreak measures from the government.

Apologies for all the delays. We still check and respond to emails.

Take care and stay well everyone! 

J&K Audio Design
19/3/2020 

Saturday, August 4, 2018

Transformer selections for isolation transformer

We've seen some fully built isolation transformers appearing on the net that is quite close to what we're offering. I guess, imitation is a kind of artless! We'd like to emphasize: get only the originals, for peace of mind, for quality, and most importantly for excellent sound (pun intended)!

What's the recommended isolation transformer for my application? We've replied this question for countless times. Therefore, it is time for a post! 

Q&As:

High power SS amplifiers, home theater amplifiers (>200W class AB, or >40W class A)
* Do not use isolation transformers unless necessary, where you are having noise, sibilance and over-voltage issue that requires some step-down.
* Isolation transformers that you can consider using are toroid (for the size / efficiency 

Lower power SS amplifiers, all tube amplifiers
* EI isolation transformers, or Ultra isolation transformers (quieter, cleaner, better!)

Sources, such as CDP, DAC, preamp
* EI Ultra isolation transformers (highly recommended), standard isolation transformers 

Toroid vs EI
* Toroid has better efficiency and therefore is more suitable for high power applications. But, toroid has higher bandwidth and therefore is not a good filter / isolation device. Toroid has more noise that leaks through primary / secondary compared to EI.
* Most importantly, EI sounds warmer, cleaner, better bass definition, less sibilance, and better body when compared to toroid. EI is the one to use if the power required is not extremely high. 
* Toroid has lesser radiated magnetic field compared to EI and may be acceptable to use un-potted but once EI is potted in metal case or have comprehensive copper bands , it will have similar behavior on radiated noise.

Grades of cores
* For toroid, we only use the highest grade silicon steel toroid core from Japan, that is only available up to 3.5KVA for now. 
* There are lower grades toroid cores with higher VA out in the market that are less efficient and have high mechanical hum. We don't use them. 
* For EI, there are several types available too. We only use Z9 for higher end units (lesser loss, runs cooler, sounds better), and Z11 for standard units (still pretty high end compared to others out there).
* The H-grade EI cores are much lower end and we try not to use them unless budget is really a concern. 

Potted vs un-potted
* Definitely potted if possible 
* Potting dissipates heat better, is mechanically damped, protects the transformer from moist/rust, avoids misalignment of the cores (EI) from abuse, and etc

Input and output taps
* If step-up or step-down is required, multiple input/primaries can be made and users can select them based on incoming mains condition
* Secondary can be multi-tapped too but is not recommended. Try with only multi-tap primaries first, such as 250-240-230-0 or 120-110-100-0 (and etc combos) to tailor to various input mains levels. 
* Secondary is recommended to be configured as balanced, aka balanced-power, such as 120-0-120 for 240Vac, or 65-0-65 for 110Vac, and so forth.

Multiple isolated outputs
* Instead of all equipment sharing the secondary and cross-pollute one another, we can build isolated secondaries in a single isolation transformer so that one can still enjoy the benefits without paying too much for dedicated isolation transformer per equipment
* Secondaries can be of multiple similar or different voltages, similar VA or different VA, balance or un-balance power (there is a limit of how many secondaries are available, try to keep to 20 taps total). 
* Extreme example is as follow
-- Primary: 250-240-230-0, 2KVA total
-- Sec1: 120-0-120, 500VA (for 240Vac for British gears)
-- Sec2: 65-0-65, 500VA (for 110Vac USA gears)
-- Sec3: 110-0-110, 500VA (for 220Vac China gears)
-- Sec4: 50-0-50, 500VA (for 100Vac Japan gears)

Standard isolation versus Ultra isolation
* Ultra isolation transformers have multitudes better noise isolation properties than standard isolation transformers 
* Ultra isolation transformers size is ~2x of standard isolation transformer to fit all the additional secret sauce and is 50-80% more expensive


Magnet wire options
* OFC (standard)
* OCC Copper (recommended for high end gears and golden ears)
* OCC Silver (for millionaires and billionaires)

Outputs
* Wire/lead out with OFC
* Wire/lead out with OCC copper or OCC silver
* Wire/lead out with original magnet wire (not for small transformers with thin wires)
* Solder tags (be warned to not over-solder, or use too high power soldering irons)
* Binding posts 

Sizing or over-sizing isolation transformers (important)
* We are already oversizing the core for cooler operation and better sound, if you want further oversizing, please inform us.
* If is oversized, output voltage may be much higher when lightly or un-loaded 
* Inform us the estimated usage so that we can custom to reduce the output voltage (ex: rated voltage at 50% load or 25% load) - VERY IMPORTANT
* Over-voltage due to light load will burn your equipment, be warned! 
* We have often seen buyers of on-the-shelf isolation transformers to suffer from over-voltage issues since the on-the-shelf isolation transformers VA are higher than needed/used.
* Multi-tap primary may help to reduce the output voltage too, such as connecting the incoming mains of 240Vac to 260Vac input tap of the transformer will effectively lowers the output voltage. 

DC Blockers
* Highly recommended for toroid isolation transformers, and recommended for EI isolation transformers
* Removes DC from the mains, transformers run cooler and have less noise electrically and mechanically
* Price varies depending on the components used, long life electrolytic capacitors are recommended since these caps pass current constantly when equipment is switched on - do not skimp here 


Soft-start
* Not required for EI isolation transformers or toroid isolation transformers with <500VA capacity.
* Recommended for toroid isolation transformers >500VA 

EMI/RFI filter modules
* Optional, may be good or bad, very system dependent, add at your own risk
* Can be placed at input or output of isolation transformers
* Results will be 50-50 (option, have dual secondaries, one with and one without) 


Due to the higher grades of core being used, prices to produce these isolation transformers are higher compared to those out there. Don't use industrial grade core products to compare to ours! Low-ballers, please save your energy.

8/5/2018
J&K Audio Design

Tuesday, June 21, 2016

Q&A



This is the Q&A database that we have collected over the years, that will be useful for interested parties. We will constantly update it whenever we have time. 

6/21/2016
Q: Can you make OPT with multiple primary and secondary taps? Will having multiple taps at primary and secondary affect the performance?
A: Yes. We can make multiple primary and multiple secondary if you still insist. Please specify which is the mostly used primary secondary tap and we will optimize those taps for the best performance. Other taps may have slightly inferior specifications. Others may have not told you the side effects but that is what happens. 

Q: I would like to specify the primary inductance to obtain the best low frequency response. Is this doable?
A: Our OPTs are usually tuned as with overall balanced sound. If you have preference of low frequency linearity versus overall bandwidth, please let us know and we will try to optimize for you – not for fixed specifications models. We cannot guarantee a certain primary inductance value but as best effort basis.

Q: Is transformer size important? I play to make an EL84 SE tube amplifier. Can I choose higher Watt OPT?
A: EL84 SE is 3W – 5W. You can choose a 5W or 10W OPT for better dynamics. Anything 4x over the intended OPT will not bring much benefits and maybe have shortcomings.

Q: Do you have standard power transformers?
A: We do not. We believe in custom made power transformers, tailored exactly to the right usage with the exact voltages needed for optimal results. Standard voltages means you need to use R/L/C to tune the voltage and that will involve compromises. If you do not know what you need, we can help you with the design.

Q: How high is the operating voltage?  
A: It depends on the transformers. We will do voltage stress testing before release – primary to secondary, and primary to core for 1 minute, according to the voltage level required for the specific transformer applications.

Q: Is potting available for all transformers?
A: It depends on the size and availability of the transformer cases.

Q: Can you make the transformers to a specific size to fit my existing chassis?
A: On case by case basis. If the application calls for core bigger than available size, then no. If it is smaller, usually it is doable. We have made adaptor plates or casing according to customer casing before. It takes longer time as we involve 3rd party to fabricate the casing.

Q: Can I customize the color of the casing?
A: It depends. Please email us and we shall try. In addition, it cannot be matched 100% too as it is controlled by 3rd party vendor. We do not make the case. We commission 3rd party vendor to make the case.

Q: Where are the transformer cores made?
A: it is made in Japan and USA.

Q: Can you use smaller transformer case?
A: We need to keep a distance between the core and the case. The case is made of ferrous materials and will generate Eddy Current (loss). If it is made of non-ferrous materials, there is not much shielding effects. That defeats the purpose of the shielding.

Q: Can I specify – primary DCR, primary inductance, feedback winding, secondary DCR, THD, noise, frequency response, withstanding voltage, specific magnet wires, Faraday shield / electrostatic shield, special cores and etc?
A: Yes, you can. We will try to accommodate all your requirements. There might or might not be price increment, depending on the customizations. Email us.

Q: Do you have combo price?
A: Yes, we do, when you order power transformer, choke and output transformers in one shot.

Q: Do you vacuum impregnate your transformers?
A: Yes, vacuum impregnation is standard process, including baking it to dry afterwards.  

Q: Will your price go up or go down in long term?
A: It will go up due to inflation, rise of materials cost, rise of labor cost, rise of everything! Order early to lock down the current price.
Q: What is the benefits of vacuum and oil immersed transformers?
A: Better protection from oxidation, better operating conditions, better sound!

Q: Your Hybrid Permalloy comes in EI core format only?
A: We have pure Permalloy C core too. Please email us if you want to have it in C core format. Do note that not all interstage / output transformers can use the Permalloy C core as we cannot interleave it with other cores to increase the power handling capacity.

Q: Can Hybrid Permalloy interstage / driver / input transformers come in bare format?
A: Interstage / driver / input transformers need shielding to isolate them from noise. They must be potted.

Q: Do you have discounts?
A: We have promotions on and off. Please check our blog regularly for latest updates.

Q: What is your lead time?
A: ~3 weeks. If there are holidays during the ordering period, or peak production time, lead time will be longer.

Q: Can you shorten your lead time?
A: Unfortunately, no.

Q: Can you customize the parameters for me?
A: Yes, we can. Please email us with details.

Q: Will your transformers specifications change in future?
A: Yes, we always try to improve our transformer designs to produce better and better design over time.

Q: Do you offer high voltage power transformers for high B+ use?
A: Yes. We can build it to withstand 1.5KV – 2KV B+. Our testing goes up as high as 4KV-5KV, depending on models.

Q: Can I have specific lead out length or solder turrets?
A: Yes. Solder turrets are only for potted transformers.

Q: Should I fully utilize the available VA for the power transformer order?
A: No, you should not. Our transformers can work at full load no doubt, but still please leave at least 25% as spares to keep the operating temperature low and for longevity purpose, not mentioning better sound! If there are too many taps, and mixture of high and low voltages, the efficiency will be lower.

Q: Where does your transformer cores come from?
A: We order from Japan and USA.

Q: Can you make vacuum and oil immersed power transformers and chokes?
A: Yes, for up to a certain size only. Please email for details.

Q: What core do you usually use for your power transformers and chokes?
A: Z10 and Z11.

Q: Will bare transformers rust?
A: Yes, they will, especially when operated near sea (on island), or near damp area. Transformer cores are made of iron and it will rust after long use even if it is painted. If you are worried of rusting, please order potted version, or add additional lacquering/painting yourself for additional protection for even longer rust protection.

Q: Can you do bifilar winding?
A: Yes, we can.

Q: Can you do solid state output transformer?
A: Yes, we can.

Q: Can you repair transformers?
A: Yes, we can. Please provide the size, pictures and weight for quotation.  

Q: How many set of windings can I have on power transformers?
A: It depends on the size of the power transformers. There are limited winding space and we usually limit it to 6 sets. Please email us if you need more than 6 so that we can evaluate if it can be fitted to that particular core size.

Q: Can you design plate choke / anode load choke?
A:  Yes, we can. Please email us the specifications and we will quote. 

Hear the Unheard.
Hear the Difference.
Only with J&K Audio Design. 

Search This Blog

Product Lists

Product Lists

Level 0: link 1

Level 1: link 1, link 2, link 3, link 4

Level 2: link 1, link 2, link 3, link 4, link 5, link 6, link 7, Link 8, link 9

Level 3: depends on type, size and complexity. Email us for details.

Iso-trans: link 1, link 2

Power-trans: link 1

* Finished amplifiers, DACs, audio gadgets, upgrades and repairs - this is not our core business and we do it out of passion. We do not have fixed models, fixed price and we customize for each individuals. The sky is limit of creativity.