Flexibility of custom isolation transformers

Why do we custom isolation transformers? Flexibility is the key advantage, among the others. Here we list a few options and actually there are more than meet the eye. 

Above i a multi-tapped primary and a balanced power output. User can connect to either one of the input based on their input primary voltage. User can also select to boost or buck the output voltage if the user connects to a higher or lower tap to achieve the desired output voltage.


Other than input voltage adaptation, and output voltage tuning, custom isolation transformers can have multiple inter-isolated outputs by having separate secondaries with different (or the same) VA to cater for different gears that have different power consumption, and input voltage requirements. Inter-isolated means the secondaries are shielded from interfering from each other rather than affecting each other for quieter operations, on top of being shielded from the primary / incoming mains. 


Above is a super flexible isolation transformer where user can fine tune to 16 combination of voltages, step-up, down, or equal. The step can be 10V-step as what's shown above, or 5V-step, or 20V-step, up to user's requirement. 


Balanced outputs can be tuned too, not just unbalanced outputs. User can have +/- 110V, or +/-120V, or others. Just let us know. 

Other than the above, another example would be to have multiple secondaries with multiple VAs and voltage requirements, connected to several output sockets so that user can connect to source, pre-amplifier, power amplifier, DAC, AV equipment, and etc. Outputs can be balanced or unbalanced, or both. 

Another even more extreme case is, in a single chassis fully built isolation transformer system, internally it can have multiple physically separated isolation transformers, each supplying to a single socket to the external world. This would save space by taking up only 1 rack space than multiple, and yet have the beauty of each equipment connecting to a separate isolation transformer. 

The possibilities are limitless. Take the advantage now and reach out to us in the left panel contact us form.

Hear the unheard!

J&K Audio Design

9/2/2025








Toroid Ultra Isolation Transformers and Toroid Ultra Isolation Power Transformers

Happy 2025 to everyone! 

There aren't nothing much to blog about after many years of research and development of various types of audio signal transformers and power transformers. In order to show that we're still alive and kicking, and most importantly, based on feedback and popular demands for higher and higher power transformers, we proudly introduce Level-3 Toroid Ultra Isolation Transformers, and Level-3 Toroid Ultra Isolation Power Transformers. 

In the previous years, we only focus on manufacturing and perfecting our EI based Level-3 Ultra Isolation Transformers. In the past 2-3 years, we have added new technologies to our Level-3 Ultra Isolation Transformers, such as these below additional / optional enhancements: 

  1. Special grounding method, called Ubiquitous Ground (UG), coupled with primary and secondary shield;
  2. Ultra Low Impedance (ULI) version for better power delivery and transient response;
  3. Ultra Low Noise Design (ULND), by doing the inverse method as audio transformers, where bandwidth is limited between primary and secondary, to filter out those unwanted signal, aka, noises; 
  4. Additional Permalloy Shield (APS), if environmental noises, either being aggressor or victim, are crucial. 

EI Level-3 Ultra Isolation Transformers are still the best of the best, but the EI transformers size are prohibitively large when it exceeds 1500VA and we seldom entertain requests to produce larger EI Level-3 Ultra Isolation Transformers. 

With the current trend of more and more high power audio amplifiers being marketed, which was a rare case decades ago, the demand for high power isolation transformers have risen significantly, where the EI Level-3 Ultra Isolation Transformers' limit of 1500VA could no longer be sufficient. In addition to that, international shipping of high transformers are expensive and we need more efficient, smaller size, lighter weight power transformers and isolation transformers for international customers. 

Therefore, the Level-3 Toroid Ultra Isolation Transformers, and Level-3 Toroid Ultra Isolation Power Transformers are born. In nature, toroid transformers are more efficient (lower magnetic flux leakage and better utilization of core), produce less electromagnetic interference (EMI) (due to the donut-shaped core design). 

Available sizes are from:

10VA to 3000VA where the largest 3000VA weights about 20KG with diameter of 250mm and 120mm height. 

Toroid cores transformers are much more efficient than EI core transformers. 3000VA EI would weight over 50KG. The Toroid Level-3 Ultra Isolation Power Transformers and Toroid Level-3 Ultra Isolation Transformers can have the same additional / optional enhancements (UG, ULI, ULND, APS) that are available on the Level-3 EI brothers. 

If power requirement is not high where 1500VA is still sufficient, the Level-3 EI Ultra Isolation Transformers and Level-3 EI Ultra Isolation Power Transformers are still the best, as naturally, EI core transformers have narrower bandwidth compared to Toroid core transformers, and with the way EI are assembled together, enabled us to implement more noise isolation and cancellation techniques. 

Either ways, you can't go wrong with either the EI or Toroid Level-3 Ultra Isolation or Isolation Power Transformers. They're much quieter, lower noise electrically and mechanically, stable, lasting, lower temperature, and many more, than the generic power transformers and isolation transformers out there. 

Reach out to us using the contact form on the left panel or drop us a PM in our FaceBook page if you need more information. 

J&K Audio Design Contact Form


Hear the unheard.

J&K Audio Design

9/2/2025

Friday, April 30, 2021

Ultra Isolation Transformer Upgrades - Ubiquitous Ground Technology

It has been quite some time since we update everyone on our J&K ultra isolation transformers. It has become better, and better, and better! We may be quiet on all fronts (FB, blogger) but we are still very active in the background. On top of our custom audio transformers, one of the other bestsellers is our J&K ultra isolation transformers that have received countless recommendations and praises.

On second half 2021, we are rolling out new grounding design for our J&K ultra isolation transformer. We call it Ubiquitous Ground Technology. Ubiquitous Ground Technology further removes or reduces the noise at the output and ground with a unique winding winding and grounding method. The noise immunity of the already super quiet output of J&K Isolation Transformer is further enhanced to an ultra low level. 

Some of our users prior to this announcement have been enjoying them since we've incorporated them in some of our recent products, free of charge. With the Ubiquitous Ground Technology being finalized and matured, we are proudly introducing it now! You can now specify to add this to your ultra isolation transformer orders. It comes with a small fee but it is definitely worth it. 

On the other hand, we would like to take this opportunity to mention the option for our J&K Ultra Isolation Transformers that we did not mention in the past - ultra low impedance transformer design. This is suitable for users in area prone to surges and spikes in their power line. It is more for protection than sound - for safeguarding and protection mostly. We usually do not offer it since it is not a small cost adder. Ask is if you prefer to have it in your order. 

P/S (important): just a note, customers have always asked us to oversize the transformers to provide more headroom. Oversizing is not bad, just that it sometimes creates other problems such as over-voltage when unloaded and also higher inrush current. So, when you order, in case we forgot to ask (apologies - we're just too busy with orders and manufacturing honestly) please indicate the actual usage so that we can adjust the winding ratio to give you more accurate desired output voltage since unloaded/lightly loaded transformers may yield higher output voltage.

Due to manufacturing being overloaded with OEM orders and everyone in J&K being overloaded, we're increasing our lead time to 4-8 weeks for custom orders, depending on design, quantity ordered, and the load at manufacturing line. 

Please plan and order early if you are in a rush. Do not order from us if you cannot wait. We do not want complications arising for long lead time - we do not want that either but it is just life. We are hiring additional technicians but it takes time to train them up PROPERLY before they can be deployed to the production line. 

We noticed that some commercial companies have been copying our design ideas from our blog posts. Shame on your but we treat it as compliment and acknowledgement to our advancement in isolation transformer technology. 

J&K Audio Design

3/4/2021

Monday, January 18, 2021

J&K Ultra Isolation Power Transformers - review from Steve McCormack

Howdy J&K followers! I hope everyone is doing extremely well and healthy in the COVID19 pandemic situation. 

We've been quite on the postings as life is really tough nowadays, juggling between pandemic, work/operations, and family. Therefore, those that are are less important, will be temporary put on-hold. Let's hope that the pandemic will be over soon and everyone can get back to their normal daily life. 

Meanwhile, we do have a GREAT news to share with everyone here. We have recently provided Steve McCormack from www.SMcAudio.net with our Level 3 Ultra Iso Power Transformers for his high performance solid-state monoblock amplifiers. He wanted the best for his customers and he got the best - a pair of state of the art power transformers made with OCC (Ohno Continuous Cast) Silver wires! 

Those who wished to have a look at the actual post, please hop on to our J&K Facebook page to check it out: https://www.facebook.com/groups/jnkaudiodesign


Quote

Hello friends of J&K Audio Design,

This is Steve McCormack writing from California. Some of you may know me from my work as an audio equipment designer, going back to McCormack Audio and The Mod Squad (long ago!). I have had my own small business for quite a while now, SMc Audio (SMcAudio.net), doing custom upgrade work on my earlier equipment and a few new pieces along the way (like my VRE-1C preamplifier and the AC Nexus power distribution and ground enhancement system). I was fortunate to recently receive a commission to build a new set of monoblock amplifiers for a client who wanted the very best work I could deliver. As part of the project, I started looking for a company that could build a set of power transformers that went well beyond any I had used previously. I am happy to say that this led me to J&K Audio and Mr. Ken Loo, who appeared to have the right sort of understanding of transformer design and the quality goals I was looking for.

Once I had let him know what my requirements were, Ken suggested his Level 3 Ultra Isolation Transformer as the best approach, so that is what we went with (configured for my amplifier, of course). My client wanted the best-possible performance, so I requested that these special parts be wound with high-purity silver wire, and that is what Ken has delivered (see photos below).
I have been building high-performance audio equipment for many years, and have done my best to source the best parts available that contribute to improved performance. I have built a lot of amplifiers and used a lot of custom transformers from well-known suppliers around the world.

Nothing I have worked with previously prepared me for the degree of superiority Ken's transformers have delivered. The sense of “you are there” realism took a major step up, along with the level of dynamic expression and engagement that I value so highly. In addition, these transformers are totally silent mechanically, and of course the degree of isolation from AC line noise is outstanding.
It may be difficult to appreciate how much sonic impact transformers with essentially the same electrical specs can have, but I assure you that the effect is very audible.

I have to thank Ken and the J&K Audio Design team for building such a superior product, and I want to urge the other fans here to consider using these transformers in your systems. From my experience, I would say that when it comes to custom magnetics for audio, Mr. Ken Loo and J&K Audio Design are the right people to work with.

Thanks again for your outstanding work on this project, Ken - it is much appreciated.

End quote

For those that are interested to know more about Steve McCormack and his gears, please head to his website www.SMcAudio.net. 

For those who like to know more about our Level 3 Ultra Isolation Power Transformers, please check out the links below: 

https://jandkaudiodesign.blogspot.com/2017/05/ultra-isolation-power-transformer.html

https://jandkaudiodesign.blogspot.com/2020/09/the-best-power-transformer-for-audio.html

https://jandkaudiodesign.blogspot.com/2016/06/isolation-transformer-bandwidth.html?m=1

https://jandkaudiodesign.blogspot.com/2017/05/ultra-isolation-power-transformer.html

Our Level 3 Ultra Isolation technology can be used in any audio gears, ranging from power transformers for solid state / tube amplifiers, to DAC or CDPs, or anything you can think of that needs power transformers. It can even be used as a standalone isolation transformer, which it was originally intended for. If you want the best of the best power transformer, look no further. 

For bargain hunters, we do have our Level 1 and Level 2 transformers that are very good in performance tooo, and is at a lower price range. Although it is our lower range products, our Level 1 and Level 2 transformers are still better than those general or even audiophile quality transformers.

Try, and you shall see. Warning - there is no turning back after you've tried our Level 3 ultra iso power transformers. They are really that good, period. 

Take care everyone, and stay safe!

J&K Audio Design

19/1/2021

UPDATE

After reading this exciting REAL USER feedback, are you excited to use our power transformers in your designs to reap the benefits not available elsewhere? We are the only one producing this for now and cannot be found elsewhere. 

We are looking for only 1-3 partners or distributors, as phase 1, due to our limited production capability, to use our ultra isolation power transformers in their finished goods. 

There are thousands, if not tens of thousands of audio equipment manufacturers out there. If you want your products to stand our from others, sound better than others, and be the best in the industry, please contact us now to be considered as our 3 sole early adopters. 

We will consider opening for more but it is not decided yet as of now, and may be a few years down the road. Your application of our ultra isolation power transformers can be made known, or classified, your choice. 

Thank you!

J&K Audio Design

6/2/2021


Wednesday, June 3, 2020

Difference between audiophile isolation transformer versus technician isolation transformer

Do you know the difference between audiophile isolation transformer (or medical isolation transformer) versus technician / electrician isolation transformer?

If you do not know, then you are in for a very severe shock, both mentally and electrically. Both of them have a very distinct difference for different usage model - and it is related to safety and noise isolation. 

If you are ordering or going to use an isolation transformer in your system, you need, you DEFINITELY MUST know this, or else, you are risking your equipment and you're risking your life it there's a fire. 

J&K single ended isolation transformer, secondary is not grounded by default. 

J&K balanced isolation transformer, secondary center-tap is grounded by default. 

For J&K customers, if you're unsure on how to use them, email us.
For J&K customers, if you need to convert to technician / electrician isolation transformer, email us. 

For followers, please wait for our write-up before you do anything drastic.

We do not have the time to quickly do the write-up yet unfortunately. Watch this space if you value your life and equipment. 

Take care! 

J&K Audio Design
3/6/2020 

Saturday, August 4, 2018

Transformer selections for isolation transformer

We've seen some fully built isolation transformers appearing on the net that is quite close to what we're offering. I guess, imitation is a kind of artless! We'd like to emphasize: get only the originals, for peace of mind, for quality, and most importantly for excellent sound (pun intended)!

What's the recommended isolation transformer for my application? We've replied this question for countless times. Therefore, it is time for a post! 

Q&As:

High power SS amplifiers, home theater amplifiers (>200W class AB, or >40W class A)
* Do not use isolation transformers unless necessary, where you are having noise, sibilance and over-voltage issue that requires some step-down.
* Isolation transformers that you can consider using are toroid (for the size / efficiency 

Lower power SS amplifiers, all tube amplifiers
* EI isolation transformers, or Ultra isolation transformers (quieter, cleaner, better!)

Sources, such as CDP, DAC, preamp
* EI Ultra isolation transformers (highly recommended), standard isolation transformers 

Toroid vs EI
* Toroid has better efficiency and therefore is more suitable for high power applications. But, toroid has higher bandwidth and therefore is not a good filter / isolation device. Toroid has more noise that leaks through primary / secondary compared to EI.
* Most importantly, EI sounds warmer, cleaner, better bass definition, less sibilance, and better body when compared to toroid. EI is the one to use if the power required is not extremely high. 
* Toroid has lesser radiated magnetic field compared to EI and may be acceptable to use un-potted but once EI is potted in metal case or have comprehensive copper bands , it will have similar behavior on radiated noise.

Grades of cores
* For toroid, we only use the highest grade silicon steel toroid core from Japan, that is only available up to 3.5KVA for now. 
* There are lower grades toroid cores with higher VA out in the market that are less efficient and have high mechanical hum. We don't use them. 
* For EI, there are several types available too. We only use Z9 for higher end units (lesser loss, runs cooler, sounds better), and Z11 for standard units (still pretty high end compared to others out there).
* The H-grade EI cores are much lower end and we try not to use them unless budget is really a concern. 

Potted vs un-potted
* Definitely potted if possible 
* Potting dissipates heat better, is mechanically damped, protects the transformer from moist/rust, avoids misalignment of the cores (EI) from abuse, and etc

Input and output taps
* If step-up or step-down is required, multiple input/primaries can be made and users can select them based on incoming mains condition
* Secondary can be multi-tapped too but is not recommended. Try with only multi-tap primaries first, such as 250-240-230-0 or 120-110-100-0 (and etc combos) to tailor to various input mains levels. 
* Secondary is recommended to be configured as balanced, aka balanced-power, such as 120-0-120 for 240Vac, or 65-0-65 for 110Vac, and so forth.

Multiple isolated outputs
* Instead of all equipment sharing the secondary and cross-pollute one another, we can build isolated secondaries in a single isolation transformer so that one can still enjoy the benefits without paying too much for dedicated isolation transformer per equipment
* Secondaries can be of multiple similar or different voltages, similar VA or different VA, balance or un-balance power (there is a limit of how many secondaries are available, try to keep to 20 taps total). 
* Extreme example is as follow
-- Primary: 250-240-230-0, 2KVA total
-- Sec1: 120-0-120, 500VA (for 240Vac for British gears)
-- Sec2: 65-0-65, 500VA (for 110Vac USA gears)
-- Sec3: 110-0-110, 500VA (for 220Vac China gears)
-- Sec4: 50-0-50, 500VA (for 100Vac Japan gears)

Standard isolation versus Ultra isolation
* Ultra isolation transformers have multitudes better noise isolation properties than standard isolation transformers 
* Ultra isolation transformers size is ~2x of standard isolation transformer to fit all the additional secret sauce and is 50-80% more expensive


Magnet wire options
* OFC (standard)
* OCC Copper (recommended for high end gears and golden ears)
* OCC Silver (for millionaires and billionaires)

Outputs
* Wire/lead out with OFC
* Wire/lead out with OCC copper or OCC silver
* Wire/lead out with original magnet wire (not for small transformers with thin wires)
* Solder tags (be warned to not over-solder, or use too high power soldering irons)
* Binding posts 

Sizing or over-sizing isolation transformers (important)
* We are already oversizing the core for cooler operation and better sound, if you want further oversizing, please inform us.
* If is oversized, output voltage may be much higher when lightly or un-loaded 
* Inform us the estimated usage so that we can custom to reduce the output voltage (ex: rated voltage at 50% load or 25% load) - VERY IMPORTANT
* Over-voltage due to light load will burn your equipment, be warned! 
* We have often seen buyers of on-the-shelf isolation transformers to suffer from over-voltage issues since the on-the-shelf isolation transformers VA are higher than needed/used.
* Multi-tap primary may help to reduce the output voltage too, such as connecting the incoming mains of 240Vac to 260Vac input tap of the transformer will effectively lowers the output voltage. 

DC Blockers
* Highly recommended for toroid isolation transformers, and recommended for EI isolation transformers
* Removes DC from the mains, transformers run cooler and have less noise electrically and mechanically
* Price varies depending on the components used, long life electrolytic capacitors are recommended since these caps pass current constantly when equipment is switched on - do not skimp here 


Soft-start
* Not required for EI isolation transformers or toroid isolation transformers with <500VA capacity.
* Recommended for toroid isolation transformers >500VA 

EMI/RFI filter modules
* Optional, may be good or bad, very system dependent, add at your own risk
* Can be placed at input or output of isolation transformers
* Results will be 50-50 (option, have dual secondaries, one with and one without) 


Due to the higher grades of core being used, prices to produce these isolation transformers are higher compared to those out there. Don't use industrial grade core products to compare to ours! Low-ballers, please save your energy.

8/5/2018
J&K Audio Design

Sunday, October 15, 2017

Isolation transformer effectiveness

Many had asked us, you have so many types of isolation transformers, which should I choose? 

Instead of repeating ourselves again and again (not that we're not willing to, but just to save everyone, and our time), here goes the effectiveness rating, from our perspective, from low (bad) to high (good), with some comments:
  1. Toroid isolation transformer (for HT, audio OK too but not warm and clean as C or EI)
    1. Up to 3.5KVA for highest grade toroid core (other grades with higher KVA are available but not recommended)
    2. >3.5KVA, go for parallel toroid for lower impedance 
  2. C core isolation transformer (for audio and HT) 
    1. Up to 1KVA (bigger size, can be custom made, up to 3KVA)
  3. EI isolation transformer (for audio and HT)
    1. Up to 3KVA
  4. C core ultra isolation transformer (for audio and HT)
    1. Up to 1KVA (bigger size, can be custom made, up to 3KVA)
  5. EI ultra isolation transformer (for audio and HT) 
    1. Up to 3KVA
Some articles about ultra isolation - article 1, article 2. 

OCC copper magnet wires (Ohno Continuous Cast) transformers are available for #2 to #5. OCC comes with a hefty price tag though. 

Benefits of OCC - lower DCR, better dynamics and clarity. We often use OCC for our output transformers, but for true audiophiles, those that hear a difference with high grade power cords, this is definitely better, and higher ROI compared to using OCC based power cords. 

Options:
* Balance or single ended outputs
* Multiple-taps isolation (explanation below) 
* Potting/frame
* Multiple shielding (electrostatic, primary/secondary, secondary/secondary
* Can be made as power transformers with isolation/ultra-isolation for SS and tube amplifiers

Multitap-isolation? 

What is multitap-isolation? Normal isolation transformers have only 1 single set of outputs, say:

- Primary: 0-240V-G
- Secondary: 120V-0-120V (balanced)

Multitap-isolation is as follow:

- Primary: 0-240V-G
- Secondary 1: 120V-0-120V (balanced, isolated/shielded from 2/3)
- Secondary 2: 120V-0-120V (balanced, isolated/shielded from 1/3)

- Secondary 3: 120V-0-120V (balanced, isolated/shielded from 1/2)

This way, instead of having multiple gears connected to a single secondary, each output is connected to 1 set of secondary to make 3 sets of ISOLATED outputs. This way, the CDP, tube preamp, and DAC (for example), are isolated from one another as they are connected to different secondary windings instead of connected altogether in a normal isolation transformer unit where all the outputs are connected to a SINGLE secondary. 

This is a MUCH better isolation scheme than normal paralleled output on-the-shelf isolation transformer unit. Yet, it is more cost effective than having 3 units of separate isolation transformer, which is the ultimate way one should do it, eventually perhaps.

Go go go, custom made audio!

J&K Audio Design
10/15/2017


Sunday, March 19, 2017

J&K Isotrans User

We had an opportunity to visit a  customer in Butterworth, Penang. He is using our EI Balanced Power Isotrans to power all his equipment, including the Burmester 032 integrated amplifier. 

The effects of using J&K Balance Power Isotrans - cleaner & darker background, more precise and proportionate imaging.

He has upgraded his integrated to Gryphon Diablo 300 recently and is saving up for his next higher power 4KVA J&K EI Balance Power Isotrans to serve the new monster that is coming soon to his setup.

We took some pictures of his setup for your enjoyment and viewing pleasures.







J&K Audio Design
3/19/2017

Thursday, June 2, 2016

Benefits of Balance Power


Benefits of balance power / isolation transformer with balance output

As a revision, a typical household mains is 240Vac (or 120Vac) referenced to ground. The neutral line is actually connected to ground at some point of the wiring in or before the house. Balance power is to have out of phase +120 and -120Vac at live and neutral lines, where it still show 240Vac when measured across both terminals +120Vac – (-120Vac) = +240Vac, and is seen by connected equipment to be no different than a normal 240Vac power.

What is the benefits of having balance power?

  • It provides very, very low noise floor in the connected electrical / electronic devices.
  • The connected equipment / systems can see increase of as high ~8x-10x dynamic range.
Why can balance power / isolation transformer with balance output make such a huge difference?
  • Power supplies does not have 100% efficiency. Portion of the returned energy are channeled back onto the source (mains/transformers) as electrical noise.
  • These returned energy cause ground noise, and is bad as all the signals are grounded to this same polluted ground line. Visualize this: 
    • All your signal cables, power cords, speaker cables, analog and digital circuits have ground pin/cable and all are shunted to ground to get rid of all the noises picked up along the way, and to use the ground as ground-reference. How important do you think it is to have a clean ground?
    • The more front end the gear is, the more important it is to have better power because the signal level is lower and the gain is higher.
      • If noise floor is high, SNR (signal-to-noise ratio) will need be low.
      • If gain is high, any noise will be amplifier significantly.
  • With conventional mains power, the returned energy rides on the neutral (a.k.a. ground) line, thus polluting it with electrical noises (voltage ripples or current spikes). 
  • With balanced mains power – returned energy stays at only live and neutral lines, and is cancelled at ground (center) line. Equal and opposite (out of phase) returned energy cancels each other, thus keeping the ground free of electrical noises. 
  • The better the power balance, the better the noise cancellation, and the wider the noise rejection bandwidth. Therefore the design of the balance isolation transformer for absolute balanced output is critical to the noise rejection.
    • Even so, a normal balanced transformer will yield better results than a normal transformer.
What do we get in terms of sound and vision?
  • Better clarity, clearer stereo imaging, more details unearthed, blacker blacks, darker background, and higher contrast.
  • If you feel that your equipment sounds and look better at a certain time of the day or night, that means you are affected by the mains and balanced power will help.
J&K Audio Design
6/2/2016


Product Lists  

Level 0

Level 3: depends on type, size and complexity. Email us for details.
Iso-trans: link 1, link 2
* Finished amplifiers, DACs, audio gadgets, upgrades and repairs - this is not our core business and we do it out of passion. We do not have fixed models, fixed price and we customize for each individuals. The sky is limit of creativity.  
* Our product lines are always improving and increasing. If you do not see what you want, contact us!  
* Please email for volume discounts, distributor and OEM pricing.

Search This Blog

Product Lists

Product Lists

Level 0: link 1

Level 1: link 1, link 2, link 3, link 4

Level 2: link 1, link 2, link 3, link 4, link 5, link 6, link 7, Link 8, link 9

Level 3: depends on type, size and complexity. Email us for details.

Iso-trans: link 1, link 2

Power-trans: link 1

* Finished amplifiers, DACs, audio gadgets, upgrades and repairs - this is not our core business and we do it out of passion. We do not have fixed models, fixed price and we customize for each individuals. The sky is limit of creativity.

* Our product lines are always improving and increasing. If you do not see what you want, contact us!

* Please email for volume discounts, distributor and OEM pricing.